Dürr · Manual electrostatic application
EcoGun AS MAN ESTA electrostatic spray guns
Handheld air spray guns with direct-charge and external-charge variants. Review the coating material, paint supply and controller requirements when choosing between EcoGun AS MAN DC and EC.

Where the DC and EC variants fit
The direct-charge benefit record covers solvent-borne and water-borne paints; water-borne applications require an insulated paint supply. The external-charge benefit record covers water-borne paints. The complete gun, controller and material-supply configuration requires review for the actual installation.
Benefits
Direct charge
- Solvent-resistant composite body for low weight and long service life
- Maximum charging voltage of 60 kV
- Direct charging
- Suitable for solvent-borne and water-borne paints; water-borne applications require an insulated paint supply
External charge
- Solvent-resistant composite body for low weight and long service life
- Maximum charging voltage of 30 kV
- Indirect charging with a compact electrode
- Suitable for water-borne paints
Technical data
All variants are included below. Scroll the table horizontally on a smaller screen.
| Specification | EcoGun AS MAN DC | EcoGun AS MAN EC |
|---|---|---|
| General information | ||
| Operation | Manual | Manual |
| Weight | 540 g | 520 g |
| Dimensions (as shown in source) | 231 × 212 × 62 | 231 × 197 × 62 |
| Material in contact with coating | Stainless steel and plastics | Stainless steel and plastics |
| Housing material | Plastic composite | Plastic composite |
| Performance | ||
| Maximum flow rate | 600–700 ml/min | 600–700 ml/min |
| Spray distance | 150–250 mm | 150–250 mm |
| Spray width (50%) | 30–360 mm | 30–360 mm |
| Viscosity | <400 mPa·s | <400 mPa·s |
| Air quality | ISO 8573-1:2010 [1:4:2] | ISO 8573-1:2010 [1:4:2] |
| Connections and pressure | ||
| Media inlet | G 3/8″ | G 3/8″ |
| Connection pressure | <6.0 bar | <6.0 bar |
| Electrical | ||
| Voltage | 20–60 kV | 10–30 kV |
| Current range | 30–80 µA | 30–80 µA |
| Environment | ||
| Operating temperature | 5–40 °C | 5–40 °C |
Values and variant designations are reproduced from the existing source records. Blank or dashed source entries are shown as “Not specified”. Confirm the exact configuration against its applicable manufacturer manual.
Manuals and order information
Order information
Open document ↗EcoGun AS MAN DC manual
Open document ↗EcoGun AS MAN EC manual
Open document ↗Source charts and references
What to prepare for an enquiry
- Coating material and whether it is solvent-borne or water-borne.
- Current gun, controller and paint-supply models.
- Part or application description and the required finish quality.
- Available drawings, part numbers and photographs of the installation.